MANTEL DEPOT
1485 Poinsettia Ave #118, Vista, CA 92081
Phone: 760-845-9313
email: MantelDepot@gmail.com
FirePlace Mantels Building Codes - National Standard
Municipal building codes are more strictly enforced as they relate to fireplaces than they are for many other decorative additions in a house.
The codes require the utmost in safety considerations because even when a fireplace is built exactly to code, it represents one of the biggest
dangers inside a residential building. Always check with your specific municipal codes to make sure that you are not going to be in violation,
whether you are installing a new fireplace or replacing one.
All the fireplace mantels on this website are non combustible and therefore require zero-clearance. This means that you can install any part of the fireplace as close as to
the fire as you want. The only requirement you need to satisfy is the hearth extension. However if you have a gas fireplace which does not burn solid fuel like woods, then
you do not need to satisfy the hearth extension requirement.
It is the
customer's responsibility to contact their local building code authority on fireplace mantels to determine if
the the mantel opening and the hearth extensions meet
the local building codes on fireplace mantels. If there is no code for mantel openings in relation to firebox openings
in your particular area, we strongly suggest the mantel surrounds meet the National Building Code.
The following is a reprint from the Standard Building Code.
2114.3 MASONRY FIREPLACES
2114.36 Fireplace hearth extensions shall be of approved noncombustible materials for all fireplaces. Where the fireplace opening is less than 6 sq.ft. (0.56mē), the hearth extension shall extend at least 16 inches (406mm) in front of the facing material and at least 8 inches (203mm) beyond each side of fireplace opening. Where fireplace opening is 6 sq.ft. (0.56mē) or larger, the hearth extension shall extend at least 20 inches (508mm) in front of the facing materials and at least 12 inches (305mm) beyond each side of the fireplace opening. Where a fireplace is elevated above or overhangs a floor, the hearth extension shall also extend over the area under the fireplace.
2114.3.7 Fireplaces constructed of masonry or reinforced concrete shall have hearth extensions of brick, concrete, stone, tile, or other approved noncombustible material properly supported and with no combustible material against the underside thereof. Wooden form or centers used during the construction of a hearth and hearth extensions shall be removed when construction is completed.
EXCEPTION: A header of combustible material may be used to support the hearth extension provided that it is located more than 12 inches (305mm) from the face of the fireplace.
2114.3.8 All combustible wood beams, joist, and studs shall be maintained a minimum of 2 inches (51mm) from the outside face of the chimney or fireplace masonry. Headers supporting trimmer arches at fireplaces shall be not less than 20 inches (508mm) from the face of the chimney breast. Trimmers shall be not less than 6 inches (152mm) from the inside face of face of the nearest flue lining.
2114.3.9 Woodwork shall not be placed within 4 inches (102mm) of the back of the fireplace, but shall not prevent plastering directly on the masonry or metal lath and metal furring.
2114.3.10 All combustible mantels and similar trim shall be kept at least 6 inches from fireplace opening. Parts of the mantel
assembly located along the sides of the fireplace opening, which project more than 1-1/2 inches (38mm) from the face of the
fireplace, shall have additional clearance equal to the projection. Parts of the mantel assembly located above and projecting
more than 1-1/2 inches (38mm) from the fireplace opening shall not be placed less than 12 inches (305mm) from the top of the fireplace opening.
-
2806 FIREPLACES FACTORY BUILT
2086.1 Factory- Built Fireplace
2806.1.1 Factory built fireplaces shall be listed and shall be installed in accordance with the conditions of the listing.
2806.1.2 Factory built fireplaces shall be tested in accordance with and meet the requirements of UL 127
2806.1.3 Hearth extensions of approved factory-built fireplace stoves shall be installed in accordance with the listing. Masonry hearth extensions if used with factory-built fireplaces shall be installed as required in 2144.3.8. The hearth extension shall be readily distinguished from the surrounding area.
2806.1.4 Factory built fireplace shall be installed in accordance with 2114.3.12
2806.2 Factory-Built Fireplace Stoves and Solid Fuel Room Heaters
2806.2.1 Factory built fireplace stoves and solid fuel type room heaters shall be listed and shall be installed in accordance with the conditions of the listing. The factory-built fireplace stoves shall be tested in accordance with and meet requirements of UL737. The solid fuel type room heaters shall be tested in accordance with and meet requirements of UL1482.
2862.2.2 Factory-built fireplace stoves shall also be installed in accordance with 2806.12 and 2114.3.12
-
2806 FIREPLACES FACTORY BUILT
False fireplaces may be used in connection with listed gas or electric heaters, provided such fireplaces are
constructed of noncombustible materials.
Please feel free to call us if you have any questions or need further clarifications on any sections of the fireplace
mantel codes or if you have any questions on our fireplace mantel materials.
Mantel Depot - America Leading Manufacturer of Exquisite Stone Fireplace Mantels and Fireplace Surrounds